Cleaver Scientific Mini Vertical systems are predominantly used for protein electrophoresis.

By combining both functionality and ease of use, the omniPAGE systems set the bench mark for simple, versatile vertical mini gel electrophoresis. Each omniPAGE electrophoresis system can accommodate up to 4 handcast gels (additional plates required) or 2 commercial precast gels to provide complete flexibility for individual research needs, while unique sliding clamp technology within the PAGE insert facilitates fast, intuitive leak-free casting.

With a trouble-free set up and consistent performance, the omniPAGE Mini Vertical systems are perfect for today’s laboratories, where the ability to generate reproducible results quickly is essential.

Description

Cleaver Logo

The perfect unit for routine vertical electrophoresis using pre-cast or hand-cast gels.The omniPAGE MINI features injection moulded construction for leak proof running,and a simple clamp system to ensure a tight seal between buffer chambers to prevent current leakage Gel casting and running is done using the same internal module,no transfer of glass plates during gel casting is necessary.The module features unique sliding gates,to allow very rapid set up of both hand cast and precast gels.Ultra soft silicone seals and pressure bars which surround the glass plates guarantee leak proof gel casting. 2mm thick glass plates minimise breakage and have bonded spacers for onvenience.

A 4-gel TETRAD system is created by simply introducing additional plates with spacers and appropriate combs. TETRAD is supplied with a casting base and external casting upstand to allow gels to be prepared in advance,ready
for the next run.

Additional information

CVS10D

Unit Dimensions (cm): 19 x 13 x 15
Weight (Kg): 1.8
Capacity: 1 – 4 Gels
Maximum Sample Capacity: 80
Base Buffer Volume: 250
Typical Running Conditions: 1-2 hours at 90-225V
Gel Dimensions: 8 x 8.5
Maximum Buffer Volume (ml): 1200
Includes Casting Base: FALSE
Blotting Insert (optional): VS10BI
2D Insert (optional): VS10DCI
Includes Additional Caster: FALSE
Plate Dimensions: 10 x 10 x 0.2

CVS10DSYS

Unit Dimensions (cm): 19 x 13 x 15
Weight (Kg): 1.8
Capacity: 1 – 4 Gels
Maximum Sample Capacity: 80
Base Buffer Volume: 250
Typical Running Conditions: 1-2 hours at 90-225V
Gel Dimensions: 8 x 8.5
Maximum Buffer Volume (ml): 1200
Includes Casting Base: TRUE
Blotting Insert (optional): VS10BI
2D Insert (optional): VS10DCI
Includes Additional Caster: FALSE
Plate Dimensions: 10 x 10 x 0.2

CVS10DSYS-CU

Unit Dimensions (cm): 19 x 13 x 15
Weight (Kg): 1.8
Capacity: 1 – 4 Gels
Maximum Sample Capacity: 80
Base Buffer Volume: 250
Typical Running Conditions: 1-2 hours at 90-225V
Gel Dimensions: 8 x 8.5
Maximum Buffer Volume (ml): 1200
Includes Casting Base: TRUE
Blotting Insert (optional): VS10BI
2D Insert (optional): VS10DCI
Includes Additional Caster: TRUE
Plate Dimensions: 10 x 10 x 0.2

CVS10PRE

Unit Dimensions (cm): 19 x 13 x 15
Weight (Kg): 1.8
Capacity: 1 – 4 Gels
Maximum Sample Capacity: 80
Base Buffer Volume: 250
Typical Running Conditions: 1-2 hours at 90-225V
Gel Dimensions: 8 x 8.5
Maximum Buffer Volume (ml): 1200
Includes Casting Base: FALSE
Blotting Insert (optional): VS10BI
2D Insert (optional): VS10DCI
Includes Additional Caster: FALSE
Plate Dimensions: 10 x 10 x 0.2